August 24, 2018

Confined space fatality

Confined space fatality – Sharp LadyThe Isle of Man Ship Registry has published Casualty Investigation Report No. CA118 on a confined space entry fatality that occurred on a crude tanker. The incident occurred after discharging crude oil. Equipment was lost at the bottom of a tank. It was decided that once the discharge was finished and crude oil washing completed, the equipment should be retrieved before loading the next cargo into this tank, to avoid any potential damage to the ship’s equipment.

The Chief Officer and Cadet entered the cargo tank after an enclosed space work permit and risk assessment had been completed. When the Chief Officer and Cadet reached the bottom of the cargo tank they felt debilitating effects of hydrocarbon vapour present at the lower level of the cargo tank. Both the Chief Officer and Cadet attempted to activate their Emergency Escape Breathing Devices (EEBD) and exit the cargo tank.
The Master observed the Cadet in difficulty and quickly entered the tank, ignoring the advice of a fellow crew member. The Chief Officer successfully exited the cargo tank but the Cadet had collapsed unconscious on the tank bottom. When the Master reached the tank bottom to aid the Cadet he was overcome by hydrocarbon vapour and collapsed.
The alarm was raised and a rescue was quickly initiated. The Master and Cadet were retrieved from the bottom of the cargo tank and brought to the main deck where first aid was administered. The report concludes that the Master died and the Cadet was injured as a result of entering the cargo tank containing a concentration of hydrocarbon vapour at the bottom of the cargo tank. The ship’s safety procedures for enclosed space were not fully complied with and the risk posed by the hydrocarbon vapour measured in the cargo tank was not appreciated by those involved in the tank entry preparations.
The report also concludes that opportunities were missed on board to stop the tank entry by several crew members and that the death of the Master could have been prevented had the safety procedures on board been followed in full.
The full report can be found at gov.im/lib/docs/ded/shipregistry/formsdocs/reports/casualty/iompg12.pdf

Source:IMCA

August 18, 2018

Cross sensitivity of detectors

During an examination of a liquefied natural gas (LNG) carrier whose cargo tanks contained ethylene vapors, CO (Carbon Monoxide) gas alarms were received which were traced to an eight-inch crack on a cargo vapor line.
It was noted that the molecular weight of Ethylene (28 g/mol) was identical to the molecular weight of CO, which accounted for the CO PPM readings.  Coast Guard personnel contacted the manufacturer who confirmed that gases such as methane, propane, ethylene and mercaptan, could actuate the CO sensor without ever coming into the range of the LEL limits.

As a result of these events the Coast Guard “strongly reminds all surveyors, marine inspectors, port state control examiners, and any other persons utilizing portable gas monitors and detectors while working onboard on Liquefied Gas Carriers to remain acutely aware that the ethylene gas vapors can exhibit cross-sensitivity.  This issue is not limited to the monitors that the Coast Guard uses but also those made by other manufacturers.  Everyone using a monitor must be aware that if the CO alarm goes off it may be an indication of dangerous gases or chemical vapors and not the presence of CO.  When the alarm sounds users must take corrective action to minimize exposure risks.”
Courtesy: USCG

August 5, 2018

Level gauge and Bromine Transportation incident

Mixed acid charging in the reactor was in progress. Level gauge of mixed acid measuring vessel broke and mixed acid splashed on the body of two employees, injuring them seriously. Root Causes: Inadequate preventive maintenance, Employees not aware about potential hazard involved in the operation.

Transportation of Bromine carried out in glass bottle having 3 Kgs capacity in wooden box by goods vehicle. During transportation few bottles broken & started leaking. Due to leakage near by area affected with bromine gas. People around the area were affected due to inhalation. Root Causes: Inadequate packing of bromine bottle. Untrained driver.

Courtesy: A.G.Shingore, National Safety Council

July 24, 2018

Loss of Primary Containment (LOPC)

Loss of Primary Containment (LOPC): An unplanned or uncontrolled release of material from primary containment, including non-toxic and non-flammable materials (e.g., steam, hot condensate, nitrogen, compressed CO2 or compressed air).


Source: CCPS Glossary