Under what circumstances might dikes be considered confined spaces and, further, when would they be permit spaces?
As a containment structure, the design of a dike will determine
whether it falls within the definition of Permit required confined space (PRCS) standard. A dike formed
of mounded or sloped earth to a height of 4 to 6 feet would not normally
represent a restricted means for entry or exit. Conversely a dike
formed of a vertical block or concrete wall of the same height would
constitute a restricted means for entry or exit.
The determination of whether a diked area determined to be a confined
space would constitute a PRCS would have to be determined based on the
hazard(s) present. For example, the potential hazard of engulfment or
the potential of a hazardous atmosphere from a heavier-than-air gas or
vapor would have to be considered in making the determination.