January 6, 2011

Major fire in depot near Rotterdam

A major fire has been reported in a tank depot near Rotterdam. The facility reportedly has 10 tanks storing chemicals.
Read the article in this link
See a youtube video in this link

Refinery cited for multiple safety hazards

OSHA has cited Pasadena Refining Services Inc. with 21 serious violations for exposing workers to multiple safety and health hazards at the company's facility in Pasadena. Proposed penalties total $115,650.
"The serious violations include failing to provide properly constructed scaffolds, provide supports to hold piping, provide controls to prevent valves from closing, conduct annual confined space audits, ensure guard rails are adequate, and ensure that operating procedures are up-to-date and accurate. A serious violation is one in which there is substantial probability that death or serious physical harm could result from a hazard about which the employer knew or should have known".

It is interesting to note that these violations have occurred even though PSM is mandatory.
Read the article in this link

January 4, 2011

Fire in oil storage depots in India

Thanks to Abhay Gujar for this info:
In the current year (2010-11) 4 instances of fires have been reported at oil depots in India:
A fire occurred at a railway siding due to spark from the overhead power line. Reason: Poor maintenance.
A fire incident took place at a Terminal's engineering store due to electrical short circuit.Reason: Poor maintenance.
Another incident took place in the cabin of TT at a Depot.Reason: Poor maintenance of TT and unsafe operating practices.
A fire broke out at a railway siding while loading.Reason: Unsafe practice and non-adherence to safety standards.The company has been advised by OISD to close the railway siding for all operations since it endangers the public life as it is close to the main Delhi-Kolkata railway track.

January 3, 2011

Risk factors in the Chemical Industry

An article mentions the risk factors identified by the American Insurance Association after investigating incidents in chemical industries. Some of them are mentioned below:
1. Factory site
(1) vulnerable to earthquakes, floods, storms natural disasters
(2) water is not sufficient
(3) the lack of public Fire Facilities support
(4) high humidity, temperature and other climate change
(5) nearby hazardous impact of large industrial installations
(6) close to highways, railways, airports and other transportation facilities
(7) difficult to safely evacuate
2. Plant layout
(1) process equipment and storage equipment is too intensive
(2) have significant risk and risk-free process safety distance between devices is not enough
(3) expensive equipment too concentrated
(4) the absence of effective protection
(5) boiler, heaters and other sources of ignition too close
(6) with terrain obstacles
3. Structure
(1) supports, doors, walls and other structures are not fire proofed
(2) Electric Equipment without protective measures
(3) inadequate capacity of explosion-proof ventilation
(4) plant is weakened (corrosion)
4. The risk of lack of knowledge of processing material
(1) hazards of mixing raw materials and natural decomposition
(2) potential for gas and dust explosions
(3) not understanding the result of misuse, or poorly controlled process
5. Chemical Technology
(1) inadequate data on the chemical reaction kinetics
(2) lack of knowledgeof the dangerous side effects
(3) does not determine the decomposition energy according to thermodynamics
(4) detection of process abnormalities is not adequate.
6. Material handling
(1) incomplete labeling of products
(2) in adequate Explosion detection/suppression device
7. Maloperation
(1) ignoring maintenance
(2)lack of supervisory role of management
(3) driving and parking plan is inadequate
(4) the lack of emergency shutdown training
(5) not establishing collaboration between operation and security personnel
8. Device Defects
(1) caused by improper selection of equipment corrosion, damage
(2) inadequate equipment, such as the lack of reliable control instrumentation
(3) material fatigue
(4) the metal material is not adequate or no inspection by experts
(5) structural defects
(6) equipment operating above design limits
9. Disaster plan
(1) did not receive strong support from management
(2) the division of responsibilities is not clear
(3) no accident prevention program

Read the article in this link.

January 2, 2011

Ammonia gas cylinder burst

An incident in an ice factory of an ammonia gas cylinder that burst killing one has occurred in West Bengal. It appears that the factory was located in a residential area and that the Municipality had renewed its licence. The article mentions
"Fire fighters risked their health and entered the factory on Saturday to repair the gas tanker. They lodged an FIR with Titagarh police against the factory owner. Officials of the Disaster Management Group (DGM) and BSF jawans also reached the spot as the tanker repair continued under their supervision. Fire officials complained that the ice factory was being run illegally in a crowded area.
"All the tankers and cylinders containing gas were in use for a long time. They had not been changed despite many tankers and cylinders being outdated. There was also no fire prevention arrangement there," said S Dubey, a senior fire official of North Barrackpore".
I often see gas cylinders being transported in autorickshaws with the cylinder cap protruding out. Authorities must be trained on the dangers of gas cylinders and its handling and transport.