Accident due to agitator lubricating fluid entering reactor

 "This report investigated the causes of a chemical release accident caused by an abnormal reaction and recommended certain safety steps to prevent the reoccurrence of similar accidents. An abnormal reaction occurred during the input of raw materials (t-BuOH, KMnO4, and H2O), and some foreign impurities (4% MeOH, 13% glycerin) that may have influenced the reaction were identified. The MeOH may have entered the reactor during t-BuOH reuse or the cleaning of mechanical parts, and glycerin was released from the seal oil reservoir to enhance lubrication with the agitator in the reactor. The pilot test carried out to reproduce the abnormal reaction revealed a rapid reaction, with an increase in the mixture temperature when the KMnO4 and glycerin (13%, released from the broken seal oil reservoir) were added to the mixture that contained 96% t-BuOH and 4% MeOH (impurity). Furthermore, some deficiencies in the safety system and some human errors were discovered. The reactor was not equipped with either a safety instrumental system or an automated emergency shutdown system, and the workers did not wear PPE. These factors could have had a significant impact on the accident".

Read the report in this link 

January 28, 2025

Hazard Alert: Combustible Dust Explosions

 Source:OSHA.Gov

Hazard Alert: Combustible Dust Explosions
Combustible dusts are fine particles that present an explosion hazard when suspended in air in certain conditions. A dust explosion can be catastrophic and cause employee deaths, injuries, and destruction of entire buildings. In many combustible dust incidents, employers and employees were unaware that
a hazard even existed. It is important to determine if your company has this hazard, and if you do, you must take action now to prevent tragic consequences 

See the link....

https://www.osha.gov/sites/default/files/publications/osha3791.pdf

January 24, 2025

DUST EXPLOSIONS CAN BE CAUSED SUBSTANCES YOU WOULD NEVER IMAGINE!

Source: OSHA.Gov: 

Does your company or firm process any of these products or materials in powdered form?
If your company or firm processes any of these products or materials, there is potential for a “Combustible Dust” explosion

https://www.osha.gov/sites/default/files/publications/combustibledustposter.pdf

January 20, 2025

Sulhur dust explosion

At 2:15 a.m. on September 17, 2019, an employee was emptying a supersack of sulfur into a bin at a tire manufacturing facility. The sulfur in the bin ignited and caused an explosion, causing the bin door to be blown open. The employee incurred burns to his face and arms from the explosion and torn ligaments in his legs as a result of the bin door striking him. The employee was hospitalized. 

 Source:OSHA.Gov

January 16, 2025

Thermal expansion of DMS caused incident

At 11:30 a.m. on June 20, 2007, Employees #1, #2, #3, and #4, who worked for Scaffolding Company, and Employees #5, and #6, who worked for Plant Services Company, and Employees #7 and #8, who worked for a chemical manufacturer, were hospitalized after being exposed to dimethyl sulfate (DMS) in the ethoxylation area where it was used in reactors 4 and 5. 

Employee #7 was an operator who moved bags containing chemicals into the area in order to add it to reactor 4. Employee #8 was a mechanic that worked unplugging an auger at reactor 4. Employees #7 and #8 started working at 7 a.m. at reactor 4. 

Employees #1, #2, #3, and #4 dismantled a scaffold at a platform at the reactors. 

 Employees #5 and #6 removed and installed new insulation on piping at a platform at the reactors. The host employer did not become aware that employees were exposed to DMS until about 2 p.m., when workers were discovered having chemical burns. Employees worked on a raised platform around the two reactors. In order to enter and leave the area, they walked along a path between two the reactors that was only 30 inches wide, and a pipe that contained DMS which ran overhead between the reactors. The piping system normally operated at 5 psi, but thermal expansion of DMS caused pressures over 300 psi and caused a valve on the overhead pipe to leak this extremely hazardous compound down onto employees that worked beneath the pipe. 

Source:OSHA.Gov