September 30, 2011

Fire in refinery

A massive blaze at a Shell refinery in Singapore has been reported.
Read and see videos about it in these links:
Refinery fire 1
Refinery fire video1
Refinery fire video 2
Refinery fire video 3


September 29, 2011

Diesel tankers accident

The Telegraph reports that "Fifteen tankers loaded with fuel were gutted and more than 10 lakh litres of diesel burnt when a goods train carrying them jumped tracks in Chanabana on the Bihar-Bengal border this morning.The inferno caused the tracks to melt, leading to disruption in train services on the Aluabari-NJP route.The heat from the burning fuel also scorched to death a villager, whose body was found after the flames were doused. Paddy on 500 acres along the tracks have been burnt.
The Northeast Frontier Railway (NFR) said the goods train, with 51 tankers and each of them filled with 70,000 litres of diesel from the Numaligarh Refineries Limited, was on its way to Jamshedpur from Maligaon in Assam. 
Read the report (with photos) in this link.

September 25, 2011

Molten Aluminium + water = explosion

An interesting theory by a scientist postulates that the twin tower collapse on 9/11 was cause by an aluminium water explosion. The article mentions the following:
"If my theory is correct, tonnes of aluminium ran down through the towers, where the smelt came into contact with a few hundred litres of water," Christian Simensen, a scientist at SINTEF, an independent technology research institute based in Norway, said in a statement released Wednesday.
"From other disasters and experiments carried out by the aluminium industry, we know that reactions of this sort lead to violent explosions." Given the quantities of the molten metal involved, the blasts would have been powerful enough to blow out an entire section of each building, he said.
This, in turn, would lead to the top section of each tower to fall down on the sections below.
The sheer weight of the top floors would be enough to crush the lower part of the building like a house of card, he said."The aluminium industry had reported more than 250 aluminium-water explosions since 1980," he said. Aluminium alloy, which in jet hulls also contains magnesium, melts at 660 degrees Celsius (1,220 degrees Fahrenheit). If heated to 750 C (1382 F), the alloy "becomes as liquid as water," Simensen said. This molten aluminium could then have flowed downward through staircases and gaps in the floor, causing a chemical reaction with water from sprinklers on the levels below.
The mix would immediately boost temperatures by several hundred degrees, releasing combustible hydrogen in the process. Such reactions are even more powerful in the presence of rust or other catalysts, which can boost temperatures to more than 1,500 C (2,700 F)."
Read the complete article in this link.



Chlorine leak incident

Thanks to Mr Harbhajan Singh Seghal for sending this incident: 
Incident:
A company in Gujarat was manufacturing Chlorinated Paraffin Wax by feeding Cl2 from the 900 kgs toner in Heavy Normal Paraffins (HNP). On the day of the incident a contract labourer disconnected the empty tonner and took the fresh 900 kgs tonner in line. Immediately after taking it in line, gas started coming out from the fitting of the copper tube at high pressure. The valve of the header and tonner was attempted to be closed by wearing SCBA. But by the time the gas had already spread. Total of 34 person were affected including 15 person from one village Out of the 15 village persons,5 were minor including a 9 month old child. All the affected persons of area were admitted in hospital. The people were complaining about breathing problem, vomiting, & loose motion but their condition was stable.
Root Cause of the Incident:
· Weak copper tube and its fittings
· Not following the correct procedure of taking the filled tonner in line
· Non availability of Safety equipment near the site and extraordinarily long time for its use.
· Non competent person handling Cl2
· Inadequate facilities for Cl2 handling
· Lack of proper training to the operating persons
Action Required:
· Copper tube and its fitting are not to be kept in the open in the atmosphere. It is to be connected with the tonner immediately
· Copper tube should be 8mm I.D., 12mm O.D. and annealed for stress relief and tested at 19.9 kg/cm2 pressure
· Ammonia torch and safety equipments should be near the installation
· While connecting the tonner, the valve should be crack opened to check for leakage. In case of minor leakage the valve is to be closed immediately
· Provision of high capacity vacuum blower to be available at site. The blower to be started in case of heavy leakage in order to avoids spreading of gas
· The operating persons should be trained to wear the safety equipment particularly SCBA in shortest possible time
· In case of leakage beyond control on site/ off site emergency should be initiated
Conclusion:
· Copper tube and its fittings have limited life. Life varies from plant to plant. The tube needs to be replaced before the established Avg. life.
· Leakage must be checked from the Cl2 tonners at the time of connection/ disconnection with ammonia torch by slightly cracking the valve in case of connection and slightly loosening the connection at the time of disconnection
· Regular drills should be conducted for usage of safety equipment and critical equipment need to be provided and tested at regular intervals.

September 23, 2011

Process Safety - union's perspective

The steelworkers union of USA has published an article mentioning that Oil refiners fail to learn from past safety incidents and near misses. This was published in 2009. The article mentions the following:
"OSHA is seeing the same problems repeatedly at refineries as it inspects them as part of its national emphasis inspection program. In the first year of the inspection program OSHA issued nearly 350 process safety management (PSM) citations to 14 refiners. The OSHA statement said the agency sent letters to the management of more than 100 oil refineries, providing them with data on compliance issues found under the emphasis program and urging them to comply with the (PSM) standard.
The API and industry are fighting us on the level of transparency and public reporting for process safety performance indicators.The goal of such transparency and public reporting is to allow refiners and petrochemical companies to learn from each other so accidents and catastrophic events are prevented.
This process also makes the companies more accountable to their workers and the communities where their refineries and petrochemical plants are located. It forces them to not just say they are being safety conscious, but to show they’re actually doing something about it".

Read the article in this link
UPDATE: An article published on Sept. 23rd, 2011 mentions the following:
"The lead negotiator for the United Steelworkers said the union representing employees at 69 U.S. oil refineries is prepared to strike if companies don’t agree to stricter safety procedures at plants and pipelines.
The USW, which failed during contract negotiations in 2009 to get companies to agree to have a USW-trained safety specialist at each refinery, will make a similar demand during talks that begin in January for a new three-year pact, Gary Beevers, a USW vice president, said today."
Read the article in this link.